Outdoor Combined Box-type Substation (European)

Outdoor Combined Box-type Substation (European)

YB series pre-installed substation has the characteristics of strong complete set, small size, compact structure, safe and reliable operation, convenient maintenance, and movable. Compared with conventional civil substations, the floor area of box-type substations with the same capacity is usually 1/10~15 of that of conventional substations, which greatly reduces the design workload and construction volume and construction costs.

*The price of the product is determined by the volume of your order. We always try to provide our customers with unique discounts and delivery times for their order.
  • DESCRIPTION
  • SPECIFICATION
  • TECHNICAL & SALES SUPPORT

Outdoor Combined Box-type Substation Description:

YB series pre-installed substation has the characteristics of strong complete set, small size, compact structure, safe and reliable operation, convenient maintenance, and movable. Compared with conventional civil substations, the floor area of box-type substations with the same capacity is usually 1/10~15 of that of conventional substations, which greatly reduces the design workload and construction volume and construction costs. In the power distribution system, it can be used in the ring network power distribution system, and PJ is also used in the dual power supply or radiation terminal power distribution system. It is a new complete set of equipment for the construction and transformation of urban and rural substations.

Outdoor Combined Box-type Substation Model:

Outdoor Combined Box-type Substation Model

Outdoor Combined Box-type Substation Application:

YB series pre-installed substation has the characteristics of strong complete set, compact structure, small size, easy to move, easy installation and maintenance. Beautiful shape, can match the color of the surrounding environment. It is suitable for installation in construction sites, factories, mines, oil fields, residential quarters, commercial centers, streets and other places. It can go deep into the load center to the maximum extent, receive electric energy, transform voltage, and supply power to low-voltage users.

Outdoor Combined Box-type Substation Technical Parameters

ItemUnitHigh voltage electrical equipmentTransformerLow voltage electrical equipment
Rated voltagekV7.2, 126/0.4, 10/0.40.4
Rated capacitykvAtype: 200~1250
type: 50~400
Rated currentA200~630100~3000
Rated breaking currentALoad switch400~630A15~63
kACombined electrical equipment is dependent on fuse
Rated short time withstand currentkA(xs)20×(2)200~400kvA15×1
(12.5×4)400kvA30×1
Rated peak withstand currentkA31.5, 50200~400kvA30
400kvA63
Rated closing currentkA31.5, 50
Line frequency withstand voltagekVPhase to earth and phase similar 32,40Oil immersion: 35/5min≤ 300V ±2kV
Isolated fracture 34,48Dry type: 28/5min300,600V ±2.5kV
Thunderstroke impactkVPhase to earth and phase similar 60,7575
Isolated fracture 75,8575
Noise leveldBOil immersion: <55
Dry type: <65