Electroslag Furnace Transformer

Electroslag Furnace Transformer

Electroslag furnace transformers are used to re-melt and refine steel made by ordinary smelting methods; they are divided into single-phase power supply and three-phase power supply, and single-phase power supply is generally used.

*The price of the product is determined by the volume of your order. We always try to provide our customers with unique discounts and delivery times for their order.
  • DESCRIPTION
  • SPECIFICATION
  • TECHNICAL & SALES SUPPORT

Electroslag Furnace Transformers Description:

Electroslag furnace transformers are used to re-melt and refine steel made by ordinary smelting methods; they are divided into single-phase power supply and three-phase power supply, and single-phase power supply is generally used. Electroslag furnace transformers do not have reactors. Electroslag metallurgy and arc steelmaking used by the arc furnace transformer is different, when the direct use of electrodes plus auxiliary steel chip method of arc slagging, only in the beginning stage of the arc, slagging is completed after the transformation into a basic arc-free slag process, this process has been continued to the end of the melting, electroslag furnace power supply transformer needs low no-load voltage and small impedance voltage. Electroslag furnace transformer low voltage to have regulation level. Voltage regulation methods are: 1, no excitation no-load voltage regulation; 2, excitation no-load voltage regulation; 3, on-load voltage regulation. Regardless of the type of voltage regulation are adjusted by the switch on the high-voltage coil.

Electroslag Furnace Transformers Features:

  • 1. computer control of remelting process in electroslag furnace
  • 2. High-precision weighing system + on-load voltage regulator transformer
  • 3. Coaxial high current power supply system
  • 4. High precision X-Y electrode adjustment system
  • 5. Hermetically sealed inert gas shield
  • 6. Electrode tip preheating device

Electroslag Furnace Transformer Application:

Temperature and Current Control: Precisely control the temperature and current density inside the electroslag furnace by adjusting the voltage and current to ensure the uniform heating and melting of metal materials and improve the melting quality and efficiency.

Electromagnetic field management: Control the electromagnetic field of electroslag furnace, reduce electromagnetic interference, protect equipment and personnel safety.

Special steel melting and metal purification: As a special power supply for electroslag remelting, electroslag furnace transformer is used for melting alloy steel, extracting high purity steel, etc. to improve the purity and quality of metal.

Continuous power supply: single-phase power supply is adopted to ensure the continuous and stable operation of electroslag furnace and reduce the production cost.

Electroslag Furnace Transformers Specification

Capacity KVA
ity
KVA
Primary KVSecondary(V)Group LabelBody WeightOil WeightTotal WeightHorizontal* VerticalL*W*H
HDG-160/0.51600.440li05002701080550×8201120×1150×1150
HDG-250/0.52500.445li06003401260550×8201150×1210×1250
HDG-270/0.52700.445-40-50li06503401350550×8201150×1300×1300
HDG-315/0.53150.445-50-55li07804201720550×8201460×1380×1300
HDGZ-315/103151060 - 30 9Levelli08506351940660×8202220×1580×2380
HDG-400/104001060-55-51-47-44li013006902960820×8202220×1570×2380
HDG-480/104801060 - 44 9Levelli0210013003800820×10202300×1800×1980
HDGZ-500/105001070 - 50 9Levelli014007102900660×10702200×2000×2070
HDG-600/106001060 - 42 9Levelli0350021006200820×10202400×2200×1980
HDG-630/106301070 - 40 8Levelli014509753150550×10702200×2050×2150
HDGZ-630/106301067-45 9Levelli014709753200550×10701900×1750×2100
HDGZ-700/107001070 - 47 9Levelli017009903900550×10701780×1800×2160
HDG-700/107001070-64-56-52-47li017509904000820×10702100×1630×2600
HDGZ-700/6.37006.370 - 47 9Levelli0179010004100550×10701780×1800×2160
HDGZ-800/108001070 - 47 9Levelli0180010604200550×10701780×1800×2160
HDGZ-800/108001087 - 60 9Levelli018809603860660×10702400×2000×2200
HDG-900/109001070-47  11Levelli0345020606100820×10202100×1900×2400
HDG-1000/1010001080-50   9Levelli0202016205350660×10702470×2250×2350
HTZ-1118/6.311186.3260-40 11LevelYaT2800230071001070×14352800×2210×2280
HDGZ-1400/61400670-45   9Levelli0240014005000660×10702160×2060×2700
HTZ-1474/6.314746.3275-60   11LevelYaT3200245076501070×14302950×2210×2430
HDGSPZ-1000/1010001080-50   17Levelli0360021506300820×10202400×1700×2800
HDGSPZ-1000/1010001082-45   19Levelli0330020005900820×10202500×1800×2700
HDGSPZ-1000/1010001092-50   23Levelli0360022006400820×10202800×1800×2900
HDGSPZ-1600/61600680-30   24Levelli0400028009800820×10703800×2050×2850
HDGSPZ-1620/1016201080-45   17Levelli05500330098001070×10703100×1700×3400
HDGSP-1620/1016201090-55   8Levelli0290020107050660×10702500×1750×2850
HDGSPZ-1620/1016201095-55   27Levelli03050400010500820×10703370×1920×3500
HDGSPZ-2200/10220010125-52   27Levelli04060510013200820×15053400×1980×3600
HDGSPZ-2400/1024001096-56   18Levelli04760510013800820×15053400×2050×3600
HDGSPZ-3150/35315035120-70   27Levelli057004300148001070×15053700×2400×4500
HDGSPZ-3400/10340010130-75   27Levelli050805000142001070×15053400×2180×3760
HZSSPZ-3000/1030001096-66   17LevelDyn1192004500172001435×14354300×2700×3500
HZSSPZ-4200/1042001085-40   25LevelDyn11102005100195001435×14353800×2800×3200
public-detail-img

Have you selected the product you like?

TECHNICAL & SALES SUPPORT